DGC-2020 Expansion Modules

Basler Electric

DGC-2020 Expansion Modules

Expand the functionality of your DGC-2020 with casy to connect and use add-on modules :
- LSM-2020 Load Sharing Module
- CEM-2020 Contact Expansion Module
- AEM-2020 Analog Expansion Module

Load Sharing (via LSM-2020 Load Sharing Module)

  • Analog output to governor (4-20mA or +/-10Vdc) Analog output to voltage regulator (4-20mA or +/-10Vdc)
  • Analog output to load share line (4-20mA or +/-10Vdc)
  • Ethernet communications
  • Generator Sequencing
  • J1939 Communications to the DGC-2020

Contact Expansion for genset applications (via CEM-2020 Contact Expansion Module)

  • Adds 10 contact inputs and 24 form C contacts to the contact-rich DGC-2020 capability.
  • Communicates to the DGC-2020 via SAE J1939 Canbus
  • Use the same model DGC-2020 genset controller for simple applications or more complicated applications that require contact functionality or duplication of contacts for remote annunciation.

 

Analog Expansion for applications requiring analog inputs/outputs and temperature monitoring (via AEM-2020 Analog Expansion Module)

  • Provides eight remote analog inputs, eight remote RTD inputs, two remote thermocouple inputs, and four remote analog outputs to the DGC-2020.
  • Communicates with the DGC-2020 through a CANbus interface.
  • The eight analog inputs are user-selectable for 4 to 20 mA or 0 to 10 Vdc, with under/over thresholds that you can configure as status only, alarm, or pre-alarm. Each can be selected and used in our powerful programmable logic software.
  • For temperature measurement, the AEM provides for eight RTD inputs that can be configured for 10 or 100 Ohm RTDs. It also has two inputs for K-type thermocouples.
  • Each of these ten temperature measurement inputs can be configured with high or low temperature thresholds and can be selected and used in our programmable logic software.
  • The analog outputs are user-selectable for 4 to 20 mA or 0 to 10 Vdc. These outputs are intended to drive external analog meters and can be configured for indication of a wide range of parameters, including oil pressure, fuel level, generator voltage, and bus voltage.

Visit www.basler.com and download Bulletin SNJ for download the product manual.